YAĞMUR SENSÖRÜ_2

Professional Line

(1518 H3) Precipitati on Sensors

Measuring element:

weighing tipping bucket • precision stainless steel bucket acc. to Joss-Tognini

Meas. range/ Resoluti on:

2 cm3-volume of bucket - 0.1 mm • 0...10 mm/min

4 cm3-volume of bucket - 0.2 mm • 0...20 mm/min

Accuracy:

± 2% with intensity compensation • controlled temperature 4 °C ± 1 °C within a range of

-35...+4 °C

Collecting surface:

200 cm2/ WMO standard

Range of application:

operating temperatures -35...+70 °C

Data of heating:

electr. controlled three-circuit heating • 235 VA total heating energy •

100 VA for ring • 100 VA for collecting funnel • 35 VA for downpipe/ bucket •

supply voltage 42 VAC

Pulse output:

reed contact · polarity protected · bounce-free signal • current consumption max.

100 μA · typical 50 μA • load max. 30 VDC/ 0.5 A • supply voltage 4...30 VDC

Housing/ Funnel + ring:

stainless steel • aluminium, anodized

Dimensions/ Weight:

H 494 mm · Ø 224 mm · for mounting pipe with Ø 60 mm · approx. 7 kg

Standards:

WMO-No. 8 · VDI 3786 page 7 · EN 50081/82 · VDE 0100

Varieti es:

00.15183.002 000

(1518 H3) Precipitati on Sensor with 2 cm3-volume of bucket

00.15183.004 000

(1518 H3W4) Precipitati on Sensor with 4 cm3-volume of bucket

Accessories: (optional)

(95666.1) TROPOS-100 Data logger (see chapter “Data logger“)